Two-Year Clinical Outcomes Following SAPIEN 3 20-mm Transcatheter Aortic Valve Implantation in Patients with Symptomatic Severe Aortic Stenosis—Comparison of the Smallest Size Valve against Larger Transcatheter Aortic Valve
-
- Kataoka Tetsuro
- NHO Kagoshima Medical Center, Kagoshima, Kagoshima, Japan
-
- Fukunaga Kengo
- NHO Kagoshima Medical Center, Kagoshima, Kagoshima, Japan
-
- Hiramine Kiyohisa
- NHO Kagoshima Medical Center, Kagoshima, Kagoshima, Japan
-
- Nomoto Yutaro
- NHO Kagoshima Medical Center, Kagoshima, Kagoshima, Japan
-
- Matsumoto Hiroyuki
- NHO Kagoshima Medical Center, Kagoshima, Kagoshima, Japan
-
- Sonoda Kohichiro
- NHO Kagoshima Medical Center, Kagoshima, Kagoshima, Japan
-
- Okino Hideto
- NHO Kagoshima Medical Center, Kagoshima, Kagoshima, Japan
-
- Tagata Kento
- NHO Kagoshima Medical Center, Kagoshima, Kagoshima, Japan
-
- Kumamoto Kengo
- NHO Kagoshima Medical Center, Kagoshima, Kagoshima, Japan
-
- Kubota Yui
- NHO Kagoshima Medical Center, Kagoshima, Kagoshima, Japan
-
- Baba Yoshimasa
- NHO Kagoshima Medical Center, Kagoshima, Kagoshima, Japan
-
- Takasaki Kunitsugu
- NHO Kagoshima Medical Center, Kagoshima, Kagoshima, Japan
-
- Nakashima Hitoshi
- NHO Kagoshima Medical Center, Kagoshima, Kagoshima, Japan
-
- Tanaka Yasuhiro
- NHO Kagoshima Medical Center, Kagoshima, Kagoshima, Japan
-
- Tokushige Akihiro
- Department of Clinical Pharmacology and Therapeutics School of Medicine, University of the Ryukyus, Nakagami-gun, Okinawa, Japan
-
- Ohishi Mitsuru
- Department of Cardiovascular Medicine and Hypertension, Graduate School of Medical and Dental Sciences, Kagoshima University, Kagoshima, Kagoshima, Japan
説明
<p>Objective: Transcatheter aortic valve implantation (TAVI) has become a cornerstone treatment for elderly or high-risk surgical patients with symptomatic severe aortic stenosis. The continuous evolution of TAVI techniques and technology has significantly improved its safety and efficacy. This study aims to deepen our understanding of the safety and effectiveness of the smallest size balloon-expanding transcatheter heart valve (BE-THV): SAPIEN 3 20 mm, through extensive utilization at our institution, with the goal of further refining TAVI procedures in the future.</p><p>Methods: This retrospective single-center observational study included 456 consecutive patients who underwent TAVI with SAPIEN 3 valves between June 2017 and October 2022. The short-term outcomes, adverse events such as stroke, new pacemaker implantation (PMI), paravalvular leak (PVL), prosthesis-patient mismatch (PPM), 30-day mortality, and 2-year mortality associated with the 20-mm THV were analyzed and compared with those of the 23-mm THV or the 26-/29-mm THV.</p><p>Results: The most commonly used THV size was 23 mm, accounting for 55.7% (254 cases), followed by the 26-/29-mm THV at 32.0% (146 cases) and the 20-mm THV at 12.3% (56 cases). There were no instances of new PMI or moderate or severe PVL observed in the 20-mm THV group. The 30-day mortality rate was 1.8% in patients who underwent the 20-mm THV, 1.6% in those with the 23-mm THV, and 0% in those with the 26-/29-mm THV, with no significant difference observed (P = 0.3012). However, the incidence of moderate PPM in patients who underwent the 20-mm THV implantation was 24.1% (13 out of 55), compared to 5.3% in those with the 23-mm THV and 4.3% in those with the 26-/29-mm THV, showing a statistically significant increase (P <0.0001), but severe PPM was not observed in any THV groups. The prevalence of a postprocedural transvalvular mean pressure gradient (MPG) ≥20 mmHg in the 20-mm THV group was higher compared to other size groups (20 mm: 14.3% vs. 23 mm: 2.0% vs 26/29 mm: 1.4%, P <0.0001). There was no significant difference in 2-year all-cause mortality rates (20 mm: 14.3% vs. 23 mm: 11.5% vs. 26/29 mm: 9.7%, P = 0.6491) among the different THV sizes.</p><p>Conclusion: The short-term outcomes associated with the 20-mm THV were reasonably satisfactory. While the occurrence of moderate PPM was significantly higher in patients receiving the 20-mm THV compared to other THV sizes, there were no significant differences in the 2-year mortality rate.</p>
収録刊行物
-
- Journal of Transcatheter Valve Therapies
-
Journal of Transcatheter Valve Therapies 6 (1), 103-111, 2024
一般社団法人 日本経カテーテル心臓弁治療学会
- Tweet
キーワード
詳細情報 詳細情報について
-
- CRID
- 1390863948815939584
-
- ISSN
- 24344532
-
- 本文言語コード
- en
-
- データソース種別
-
- JaLC
- Crossref
- OpenAIRE
-
- 抄録ライセンスフラグ
- 使用不可