Off axis PIV approach has been introduced to obtain 3 dimension 3 component velocity vector field of Taylor column. This method makes it possible to reconstruct vector field by a single camera setting because its PIV measurement plane surface is slightly offset toward rotating axis. This approach was applied to Taylor Column which has circumferential instability. The fully reconstructed vector field shows the structure of Taylor column twist around the rotating axis as the distance from the disk increase.