Description
Previous papers by the author have proven that thermography could be successfully used in the detection of fault ICs. This paper shows that thermography can also be effectively used as a tool to detect IC deterioration.The results obtained from the tests performed on the control board monitor PCB of the East JR Co. Ltd Shinkansen are shown.The results obtained showed that about 30% of the chips tested have deteriorated. Moreover,this fact was verified by heating the ICs and measuring the IC temperatures on the PCBs.Furthermore,the high temperature exhibited by the ICs confirmed their deterioration.