Velocity of ultrasound,acoustic impedance and reflectivity. measured on arterial walls.
-
- Arai Tsutomu
- Division of Biomedical Engineering,Faculty of Engineering,Hokkaido University.
-
- Nishihira Morimasa
- Division of Biomedical Engineering,Faculty of Engineering,Hokkaido University.
-
- Futamura Tomoaki
- Division Electric Information Engineering,School of Engineering, Hokkaido Tokai University.
-
- Yamamoto Katsuyuki
- Division of Biomedical Engineering,Faculty of Engineering,Hokkaido University.
Bibliographic Information
- Other Title
-
- 動脈壁の音速,音響インピーダンス,および反射率の計測
Search this article
Description
In recent years,many studies on ultrasound measurement of the artery have been performed.However,acoustic properties of blood vessels,which are the bases of the ultrasound measurement,are little known.We measured the velocities of ultrasound,the acoustic impedance and the reflectivities of the aorta at 37 ℃ in rabbits u sing a new technique.The mean values of the velocity,the density and the impedance were 1601 ± 12 m, s,1.0719 ± 0.0004 g/cm[^3[^ a nd 1.716 g/cm[^2]/s,respectively.We measured also the reflectivities under the various hematocrit values of blood.The reflectivity decreased linearly with the hematocrit and showed the lowest value less than 1% around the normal hematocrit.
Journal
-
- IEICE technical report. ME and bio cybernetics
-
IEICE technical report. ME and bio cybernetics 94 93-98, 1994
The Institute of Electronics, Information and Communication Engineers
- Tweet
Details 詳細情報について
-
- CRID
- 1571980077337178880
-
- NII Article ID
- 110003287383
-
- NII Book ID
- AN10013050
-
- Text Lang
- ja
-
- Data Source
-
- CiNii Articles