Fabrication of Drung Type SQUID

Bibliographic Information

Other Title
  • Drung式SQUID素子の製作

Search this article

Description

Drung-type SQUID with asymetric bias injection were fabricated. Consideration of the direction of APF coil has lead to a stational characteristics of Φ-V curves at the largest dV, dΦ. IcR product is found to be a good predictor for voltage swing,dV, dΦandΦn.Measurement of run-to-run variations showed that a mass production of SQUID with 4.0-fT/√Hz> resolution is possible

Journal

  • Technical report of IEICE. SCE

    Technical report of IEICE. SCE 93 (279), 55-60, 1993-10-20

    The Institute of Electronics, Information and Communication Engineers

Details 詳細情報について

  • CRID
    1572543027266872704
  • NII Article ID
    110003187449
  • NII Book ID
    AN10012885
  • Text Lang
    ja
  • Data Source
    • CiNii Articles

Report a problem

Back to top