Reliability of PLC-Type Optical Modules for Access Networks

Bibliographic Information

Other Title
  • 光アクセスシステム用PLC型光部品の信頼性

Search this article

Description

Reliability of PLC-type optical splitters and transceiver modules for access networks is examined. A life test on optical splitters is performed in environments with various temperatures and humidities, and a 30-year hazard rate of less than 220 FIT is estimated for splitters operating at an ambient of 60℃40%RH. A temperature-humidity test and a temperature-humidity-bias test are performed on transceiver modules, and a filter-embedded multiplexer and optical semiconductor devices in the transceiver module are confirmed to be durable at 75℃90%RH.