Simulation of Unsteady 3-D Wet-Steam Flows Through Three-Stage Stator-Rotor Blade Rows With Equilibrium and Nonequilibrium Condensations
説明
<jats:p>Unsteady 3-D wet-steam flows through three-stage stator-rotor blade rows in a low-pressure steam turbine model developed by Mitsubishi Heavy Industry (MHI) are numerically investigated. In this study, a new and simple meshing strategy is introduced to improve the prediction of end-wall flows near the shroud and the hub. Dry and wet-steam conditions are taken into account and the calculated results changing the grid system are compared with the experiments. As a practical usage, coarse-grid computations using a PC cluster are also conducted and the results are compared with those using a fine grid and a supercomputer. In addition, a super-cooled condition is assumed and the computation is further conducted. Finally, the effect of homogeneous nucleation and the nonquilibrium condensation on the present flow is evaluated.</jats:p>
収録刊行物
-
- Volume 6: Oil and Gas Applications; Concentrating Solar Power Plants; Steam Turbines; Wind Energy
-
Volume 6: Oil and Gas Applications; Concentrating Solar Power Plants; Steam Turbines; Wind Energy 505-513, 2012-06-11
American Society of Mechanical Engineers