Efficiency and noise measurements of non-uniformly irradiated double-sided silicon strip detectors
Search this article
Description
Abstract We have investigated the efficiency and the noise occupancy of double-sided silicon strip detectors, which were subjected to non-uniform proton irradiation of fluences up to a maximum of equivalent 5 × 10 13 protons/cm 2 . The depletion voltages, varying over time due to controlled annealing, were close to zero on one end of the 6 cm strips and 190 V at the high radiation end. We determined the efficiency and noise occupancy on both n-side and p-side in a 106 Ru telescope, using a binary read-out system with 22 ns shaping time. The n-side exhibits superior performance after type inversion.
Journal
-
- Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
-
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 383 174-178, 1996-12-01
Elsevier BV
- Tweet
Details 詳細情報について
-
- CRID
- 1870302168258642048
-
- ISSN
- 01689002
-
- Data Source
-
- OpenAIRE