Performance of the single-pass position monitor at SOR-RING
説明
The R&D of single-pass beam position monitor is being carried out at SOR-RING, a 500-MeV electron storage ring. The bunch signals from four button electrodes are directly fed into a 4-channel digital oscilloscope through semi-rigid cables. The digitized data are sent to a workstation for the beam position calculation. The relative accuracy much less than 0.1 mm has been obtained with this system.
収録刊行物
-
- Proceedings of the 1997 Particle Accelerator Conference (Cat. No.97CH36167)
-
Proceedings of the 1997 Particle Accelerator Conference (Cat. No.97CH36167) 2 2146-2148, 2002-11-22
IEEE