Determination of electron beam radius at the cavity in gyrotron FU CW I
Description
A 300 GHz fully continuous wave gyrotron FU CW I has been developed for application to material processing in the submillimeter wave range. The output power from this gyrotron has not reached the designed one. As a reason of power shortage, it is considered that the electron beam radius shifts from the optimum radius due to installation of additional gun coils to suppress a large anode current. For improvement of the output power, the present beam radius is determined from measurement. With the determined radius, the cause of power shortage is discussed.
Journal
-
- 2009 34th International Conference on Infrared, Millimeter, and Terahertz Waves
-
2009 34th International Conference on Infrared, Millimeter, and Terahertz Waves 1-2, 2009-09-01
IEEE