Development of High Resolution X-Ray CT Technique for Highly-Radioactive Material

この論文をさがす

説明

<jats:title>ABSTRACT</jats:title><jats:p>In order to observe the structural change in the interior of irradiated fuel assembly, the non-destructive post irradiation examination technique using X-ray computer tomography (X-ray CT) was developed.</jats:p><jats:p>In this X-ray CT system, the 12 MeV X-ray pulses were used in synchronization with the switch-in of the detector in order to minimize the effects of the gamma ray emissions from the irradiated fuel assembly then clear cross section CT image of irradiated fuel assembly could be successfully obtained. Also, this non-destructive technique can be applied to observe the inner condition of the high radioactive materials such as a radioactive waste.</jats:p>