Late Abnormal Vessel Wall Reaction 3 Years After Sirolimus-Eluting Stent Implantation

DOI オープンアクセス

この論文をさがす

説明

A 67-year-old man with stable angina and 1-vessel coronary disease underwent successful percutaneous intervention with 2 overlapping sirolimus-eluting stents (3.5 mm in diameter, 18 mm long; and 3.5 mm in diameter, 23 mm long; Cypher, Cordis, Johnson & Johnson Company, Miami Lakes, Fla) in the mid portion of the right coronary artery in July 2006. In February 2007, follow-up angiography confirmed patency of the stent. In February 2009, the patient was readmitted with recurrence of effort angina 32 months after the index procedure. Repeat angiography showed severe …