Time-resolved oblique incidence interferometer for vibration analysis of rough surface

この論文をさがす

説明

This paper describes a motion-visualization technique for a sample with rough surface by using a stroboscopic oblique-incidence interferometer. To observe a vibrated rough surface, we focused on an oblique-incidence interferometer. The oblique-incidence interferometer is well suited to analysis the rough surface and a displacement of several micrometers because a scattering at a rough surface is reduced. However, by using a continuous light, a visibility of the fringe pattern at a vibrated surface in the ultrasonic region is not good. Therefore, the oblique-incidence interferometer is not suitable for analysis of the ultrasonic vibration. To overcome the problem, a pulsed light synchronized with a vibrated sample was used as a light source by an acousto-optic modulator. To control timing between a reference signal and an input signal of the light source by using a common oscillator, time-resolved behavior of the stator can be measured. By using the interferometer, we have succeeded to detect a periodically movement of a fringe pattern of the vibrated of the stator.

収録刊行物

詳細情報 詳細情報について

  • CRID
    1871991017725312896
  • DOI
    10.1117/12.889464
  • ISSN
    0277786X
  • データソース種別
    • OpenAIRE

問題の指摘

ページトップへ