Evoked spinal electrogram in a quadriplegic patient

この論文をさがす

説明

Abstract The somatosensory evoked spinal electrogram (ESEG) was recorded from the dorsal epidural space and from anterior intrathecal space in a quadriplegic patient. The “segmental” ESEG, recorded intrathecally from the antero-lateral surface of the cord, showed deflections with reversed polarity to those recorded from the dorsal epidural space. The ESEG evoked by the direct stimulation of the spinal cord showed a similar pattern to that evoked by peripheral nerve stimulation. Thus, the ESEG in this quadriplegic patient showed a pattern similar to that in the normal subject.