- 【Updated on May 12, 2025】 Integration of CiNii Dissertations and CiNii Books into CiNii Research
- Trial version of CiNii Research Knowledge Graph Search feature is available on CiNii Labs
- Suspension and deletion of data provided by Nikkei BP
- Regarding the recording of “Research Data” and “Evidence Data”
Drug Delivery System Using Nano-Magnetic Fluid
Description
Nano-size magnetic magnetide is considered important for various medical applications. Dynamic motion of the magnetic particle is investigated in two essential models from a theoretical point of view. One is a drag model of the magnetic particle in an artery. The second is a pull model towards the surface of artery. Threshold conditions of external variables are obtained by dimensional analysis. On the basis of all these results, it is concluded that the movement of magnetic fluids can be controlled by external magnetic fields in blood vessels.
Journal
-
- 2008 3rd International Conference on Innovative Computing Information and Control
-
2008 3rd International Conference on Innovative Computing Information and Control 338-338, 2008-01-01
IEEE