Bathroom watching using a breath detection system

この論文をさがす

説明

Recently, domestic accidents have been increasing in Japan. These kinds of accidents occur in private areas such as bedrooms, toilets and bathrooms, and tend to be found too late. Accidents, particularly those occurring in the bathroom, can often result in death. Many systems which have been proposed or which are in use are designed to detect body motion in the bathroom, and determine that a bather has suddenly taken ill when movement ceases. However, the relaxed posture of a person bathing is actually very similar to that of a person who has passed out. It is therefore very difficult to differentiate between the two postures. We have developed a watching system for bathrooms. The new feature of this system lies in its ability to detect a person’s breathing by using an FG vision sensor. From the experiment, it was found that the false alarm rate is expected to reach less than 0.0001% when waiting time is set to 36.8 seconds.

収録刊行物

詳細情報 詳細情報について

  • CRID
    1872272493077043328
  • DOI
    10.1117/12.571135
  • ISSN
    0277786X
  • データソース種別
    • OpenAIRE

問題の指摘

ページトップへ