Biofeedback control analysis using a synchronized system of two CCD video cameras and a force-plate sensor
この論文をさがす
説明
The biofeedback control analysis of human movement has become increasingly important in rehabilitation, sports medicine and physical fitness. In this study, a synchronized system was developed for acquiring sequential data of a person's movement. The setup employs a video recorder system linked with two CCD video cameras and fore-plate sensor system, which are configured to stop and start simultaneously. The feedback control movement of postural stability was selected as a subject for analysis. The person's center of body gravity (COG) was calculated by measured 3-D coordinates of major joints using videometry with bundle adjustment and self-calibration. The raw serial data of COG and foot pressure by measured force plate sensor are difficult to analyze directly because of their complex fluctuations. Utilizing auto regressive modeling, the power spectrum and the impulse response of movement factors, enable analysis of their dynamic relations. This new biomedical engineering approach provides efficient information for medical evaluation of a person's stability.
収録刊行物
-
- SPIE Proceedings
-
SPIE Proceedings 3570 217-, 1999-01-15
SPIE