Effects of Slowly Performed Daytime Hemodialysis (Slow HD) on the Pharmacokinetics of Vancomycin in Hemodynamically Unstable Patients with Renal Failure

この論文をさがす

説明

Effects of slowly performed daytime hemodialysis (slow HD) using a high-flux hemodialyzer on the pharmacokinetics of vancomycin were determined in 5 critically ill patients with renal failure. Following intravenous administration of 0.5 g of vancomycin, concentrations in the serum and dialysate were monitored. Pharmacokinetic parameters were calculated after fitting individual concentration-time curves to a two-compartment model. The volume of distribution at steady state was 0.58 +/- 0.12 liters/kg. Total body clearance was 37.46 +/- 3.20 ml/min with an elimination phase half-life of 8.72 +/- 0.99 h. Slow HD clearance was 20.19 +/- 2.30 ml/min. During a 10-hour session of slow HD, the serum vancomycin concentration decreased from 44.2 +/- 3.8 to 10.0 +/- 5.0 mg/l and 30.10 +/- 5.34% of the dose was eliminated. Dialyzer clearance of this drug and urea was 18.71 +/- 1.40 and 28.77 +/- 1.77 ml/min, respectively. Slow HD may effectively eliminate vancomycin by a diffusive mechanism and this elimination should be taken into consideration for designing the dosage schedule during the treatment.

収録刊行物

詳細情報 詳細情報について

  • CRID
    1873116917854877440
  • DOI
    10.1159/000170237
  • ISSN
    14219735
    02535068
  • PubMed
    8718561
  • データソース種別
    • OpenAIRE

問題の指摘

ページトップへ