The Infrared Imaging Spectrograph (IRIS) for TMT: prototyping of cryogenic compatible stage for the imager

DOI DOI オープンアクセス

この論文をさがす

説明

The IRIS Imager requires opt-mechanical stages which are operable under vacuum and cryogenic environment. Also the stage for the IRIS Imager is required to survive for 10 years without maintenance. To achieve these requirements, we decided prototyping of a two axis stage with 80 mm clear aperture. The prototype was designed as a double-deck stage, upper rotary stage and lower linear stage. Most of components are selected to take advantage of heritage from existing astronomical instruments. In contrast, mechanical components with lubricants such as bearings, linear motion guides and ball screws were modified to survive cryogenic environment. The performance proving test was carried out to evaluate errors such as wobbling, rotary and linear positioning error. We achieved 0.002 $\rm deg_{rms}$ wobbling, 0.08 $\rm deg_{0-p}$ rotational positioning error and 0.07 $\rm mm_{0-p}$ translational positioning error. Also durability test under anticipated load condition has been conducted. In this article, we report the detail of mechanical design, fabrication, performance and durability of the prototype.

10 pages, 9 figures, Proceeding 9908-380 of the SPIE Astronomical Telescopes + Instrumentation 2016