A negative hysteresis threshold circuit and its analysis†
この論文をさがす
説明
Abstract It is well known that there is a hysteresis effect in the Schmitt trigger circuit. In the present paper, the author proposes a negative hysteresis threshold circuit which consists of a cathode-coupled trigger circuit with a CR delayed feedback loop. This circuit can be set to remove any hysteresis by adjusting the delayed feedback loop gain. A non-linear analysis is developed on the above circuit, using the phase-plane method together with the experimental results.
収録刊行物
-
- International Journal of Electronics
-
International Journal of Electronics 34 641-653, 1973-05-01
Informa UK Limited