Characterization of cable plasma guns for microsecond plasma opening switch
説明
Cable plasma guns are frequently used as a plasma source in plasma opening switches. The authors' plasma guns are designed for use in a 400 kA inductive voltage adder with an inductive energy storage system. The plasma source consists of eight cable guns mounted on an outer coaxial electrode. The characteristics of the plasma generated by the cable plasma guns have been investigated using a laser interferometer. The contour maps of the plasma density of the whole area between the electrodes are plotted as a function of time.
収録刊行物
-
- Digest of Technical Papers. 12th IEEE International Pulsed Power Conference. (Cat. No.99CH36358)
-
Digest of Technical Papers. 12th IEEE International Pulsed Power Conference. (Cat. No.99CH36358) 2 1183-1186, 2003-01-22
IEEE