High-power aging tests of 1.3 and 1.5 μm VIPS lasers
この論文をさがす
説明
1.3 and 1.5 μm VIPS lasers were tested under high-power aging levels up to 130 mW. The output powers of the lasers were enhanced by AR/HR-coating of facets and optimisation of cavity lengths. Aging power levels were 75% of ?Pmaxand were up to 130mW at 25°C and up to 90 mW at 70°C for 1.3μm VIPS lasers. The median lifetimes were estimated to be 150,000 h at 25°C and 60,000 h at 70°C. For the 1.5μm VIPS lasers, the aging power levels were up to 90 mW at 25°C and up to 50 mW at 70°C. Median lifetimes of about 60,000 h and 45,000 h for 25 and 70°C aging tests, respectively, were achieved.
収録刊行物
-
- Electronics Letters
-
Electronics Letters 23 843-844, 1987-07-30
Institution of Engineering and Technology (IET)