説明
Inorganic anions could be separated on porous graphitic carbon stationary phases in ion chromatography. Ion exchange between eluent anions and sample anions on the stationary phase was confirmed by the retention behavior and the possibility of indirect photometric detection. The elution order of anions was different from that observed for commercially available anion exchangers. Chloride, nitrate, and sulfate contained in tap water could be determined in 7 min.
収録刊行物
-
- Journal of High Resolution Chromatography
-
Journal of High Resolution Chromatography 23 590-594, 2000-10-01