Micro-Vibration Patterns Generated from Shape Memory Alloy Actuators and the Detection of an Asymptomatic Tactile Sensation Decrease in Diabetic Patients
書誌事項
- タイトル
- Micro-Vibration Patterns Generated from Shape Memory Alloy Actuators and the Detection of an Asymptomatic Tactile Sensation Decrease in Diabetic Patients
- 著者
- 檀上, 淳一
- 著者別名
-
- Danjo, Junichi
- ダンジョウ, ジュンイチ
- 学位授与大学
- 香川大学
- 取得学位
- 博士(医学)
- 学位授与番号
- 甲第648号
- 学位授与年月日
- 2016-12-27
説明
Diabetes mellitus is a group of metabolic diseases that cause high blood sugar due to functional problems with the pancreas or metabolism. Diabetic patients have few subjective symptoms and may experience decreased sensation without being aware of it. The commonly performed tests for sensory disorders are qualitative in nature. The authors pay attention to the decline of the sensitivity of tactile sensations, and develop a non-invasive method to detect the level of tactile sensation using a novel micro-vibration actuator that employs shape-memory alloy wires. Previously, we performed a pilot study that applied the device to 15 diabetic patients and confirmed a significant reduction in the tactile sensation in diabetic patients when compared to healthy subjects. In this study, we focus on the asymptomatic development of decreased sensation associated with diabetes mellitus. The objectives are to examine diabetic patients who are unaware of abnormal or decreased sensation using the quantitative tactile sensation measurement device and to determine whether tactile sensation is decreased in patients compared to healthy controls. The finger method is used to measure the Tactile Sensation Threshold (TST) score of the index and middle fingers using the new device and the following three procedures: TST-1, TST-4, and TST-8. TST scores ranged from 1 to 30 were compared between the two groups. The TST scores were significantly higher for the diabetic patients (P<0.05). The TST scores for the left fingers of diabetic patients and healthy controls were 5.9±6.2 and 2.7±2.9 for TST-1, 15.3±7.0 and 8.7±6.4 for TST-4, and 19.3±7.8 and 12.7±9.1 for TST-8. Our data suggest that the use of the new quantitative tactile sensation measurement device enables the detection of decreased tactile sensation in diabetic patients who are unaware of abnormal or decreased sensation compared to controls.
- Tweet
キーワード
詳細情報 詳細情報について
-
- CRID
- 1910020910703304832
-
- NII論文ID
- 500001434090
- 500001625415
- 500001075262
-
- 本文言語コード
- en
-
- データソース種別
-
- IRDB
- NDLサーチ