差圧式質量流量計

DOI

書誌事項

タイトル別名
  • Mass Flowmeter of Pressure Difference Type

抄録

The mass fiowmeter of pressure difference type, here reported, resembles Simmonds' mass fiowmeter and the essential difference between them is that the latter has two orifices while the former none. It is found that the theory of Simmonds' mass fiowmeter given by himself is in error, and a correct theory of Simmonds' mass flowmeter is developed in this paper. The mass fiowmeter newly devised is simpler in construction than that by Simmonds. It is experimentally verified that mass flowrate can be obtained by the newly devised mass fiowmeter of pressure difference type.

収録刊行物

  • 応用物理

    応用物理 37 (4), 334-338, 1968

    公益社団法人 応用物理学会

詳細情報 詳細情報について

  • CRID
    1390001204629001472
  • NII論文ID
    130003588733
  • DOI
    10.11470/oubutsu1932.37.334
  • COI
    1:CAS:528:DyaF1cXksVCkur4%3D
  • ISSN
    21882290
    03698009
  • データソース種別
    • JaLC
    • CiNii Articles
  • 抄録ライセンスフラグ
    使用不可

問題の指摘

ページトップへ