- 【Updated on May 12, 2025】 Integration of CiNii Dissertations and CiNii Books into CiNii Research
- Trial version of CiNii Research Automatic Translation feature is available on CiNii Labs
- Suspension and deletion of data provided by Nikkei BP
- Regarding the recording of “Research Data” and “Evidence Data”
A High Accuracy and Simple Analytical Method for Microcystins Using <sup>15</sup>N-labeled Microcystins
-
- SANO TOMOHARU
- Nationl Institute for Environmental Studies
-
- TANAKA YOSHITO
- Fukuoka Institute of Health and Environmental Sciences
-
- TOBIISHI KAZUHIRO
- Fukuoka Institute of Health and Environmental Sciences
-
- ARAHORI YASUSHI
- Nara prefecture Landscape Environmental Center
-
- SHIMIZU AKIRA
- Chiba Prefectural Environmental Research Center
-
- SATO CHIZUKO
- Miyagi Prefectural Institute of Public Health and Environment
-
- KAYA KUNIMITSU
- Nationl Institute for Environmental Studies
Bibliographic Information
- Other Title
-
- <sup>15</sup>N標識ミクロシスチンを用いた簡便で高精度なミクロシスチン分析手法
- A High Accuracy and Simple Analytical Method for Microcystins Using ¹⁵N-labeled Microcystins
Search this article
Description
Microcystins, cyclic heptapeptide hepatotoxins, are the most frequently detected from freshwater cyanobacteria around the world. WHO recommended a guideline value of microcystin-LR that the dosage should be below 1 μg・L-1 in drinking water. To monitor microcystins concentration in water, LC-MS/MS has been used. However, ionization efficiencies of internal standards are different from those of microcystins. As the results, the accuracy of microcystin determination is not enough for the monitoring.To improve the accuracy, we developed a simple and precise method using stable isotope (15N)-labeled microcystin. As procedures, a frozen water-sample (0.5 mL) was thawed and added 15N-labeled microcystin with 0.5 mL of MeOH. After ultra-sonication for 10 min of the treated sample, the sample solution was filtered using 0.22 μm membrane filter. The filtrate was injected to LC-MS/MS and quantified. The limit of quantification was around 0.1 μg・L-1 depended on the instrument sensitivity. Using this method, high accurate quantified results of microcystins in water sample were obtained.
Journal
-
- Japanese Journal of Water Treatment Biology
-
Japanese Journal of Water Treatment Biology 52 (1), 31-34, 2016
Japanese Society of Water Treatment Biology
- Tweet
Details 詳細情報について
-
- CRID
- 1390001204963133952
-
- NII Article ID
- 130006471097
-
- NII Book ID
- AN00351126
-
- ISSN
- 18810438
- 09106758
-
- NDL BIB ID
- 027224519
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- NDL Search
- Crossref
- CiNii Articles
- OpenAIRE
-
- Abstract License Flag
- Disallowed