Measurement for the Interocciusal Ditances at Maximum Intercuspation using a bundle of Registration Strips

DOI

Bibliographic Information

Other Title
  • レジストレーション・ストリップスを用いた咬頭嵌合位における咬合面間距離の計測

Search this article

Description

The interocclusal distances of the upper and lower study models mounted on a semi-adjustable articulator are in maximum Intercuspation were measured, using a bundle of registration strips. The average interocclusal distance was 0.10±0.10mm for the molars. Providing the diameter of man's hair is about 30 microns, then three hairs will pass through the clearance between upper and lower teeth in maximum intercuspation.