Flow-induced Vibration of Large-diameter Elbow : (2) Flow-induced Random Vibration Force Distribution and Correlation Analysis
-
- ISHITANI Yoshihide
- Mitsubishi Heavy Industries Ltd.
-
- NAKAMURA Tomomichi
- Mitsubishi Heavy Industries Ltd.
-
- SAGO Hiromi
- Mitsubishi Heavy Industries Ltd.
-
- SHIRAISHI Tadashi
- Mitsubishi Heavy Industries Ltd.
-
- WATAKABE Hisato
- Mitsubishi Heavy Industries Ltd.
-
- KONOMURA Mamoru
- Japan Nuclear Cycle Development Institute
-
- YAMAGUCHI Akira
- Japan Nuclear Cycle Development Institute
-
- FUJII Tadashi
- Japan Nuclear Cycle Development Institute
Bibliographic Information
- Other Title
-
- 大口径エルボ管の流動励起振動に関する研究 : 第2報:励振力分布と相関分析(J13-6 流体関連振動III,J13 流体関連の騒音と振動)
Description
A 1/3scale flow-induced vibration test facility that simulates a hot-leg piping of the Japanese sodium-cooled fast reactor (JSFR) is used to investigate the pressure fluctuations of the pipe. To evaluate the flow-induced vibrations for the hot-leg and cold-leg pipes, the random force distributions along the pipe and their correlations are estimated. As the result, the power spectrum densities of pressure fluctuations are classified into four sections, the correlation lengths of axial direction into three sections, and the correlation lengths of tangential direction into four sections. The maximum flow-induced random vibration force in the pipe is estimated in the region of flow separation downstream the elbow.
Journal
-
- The proceedings of the JSME annual meeting
-
The proceedings of the JSME annual meeting 2004.7 (0), 105-106, 2004
The Japan Society of Mechanical Engineers