- Flow-induced Vibration of Large-diameter Elbow : (2) Flow-induced Random Vibration Force Distribution and Correlation Analysis
説明
A 1/3scale flow-induced vibration test facility that simulates a hot-leg piping of the Japanese sodium-cooled fast reactor (JSFR) is used to investigate the pressure fluctuations of the pipe. To evaluate the flow-induced vibrations for the hot-leg and cold-leg pipes, the random force distributions along the pipe and their correlations are estimated. As the result, the power spectrum densities of pressure fluctuations are classified into four sections, the correlation lengths of axial direction into three sections, and the correlation lengths of tangential direction into four sections. The maximum flow-induced random vibration force in the pipe is estimated in the region of flow separation downstream the elbow.
収録刊行物
-
- 年次大会講演論文集
-
年次大会講演論文集 2004.7 (0), 105-106, 2004