書誌事項
- タイトル別名
-
- On the reading errors of hot wire close to the wall.
- ヘキメン チカクニ オケル ネッセン フウソクケイ ノ ソクテイ ゴサ
この論文をさがす
説明
When we measure the velocity close to a wall using a hot wire anemometer, the measuring errors of the velocity may be caused due to the heat loss from the ware to the wall. In a laminar boundary layer on a flat plate, these errors were experimentally shown depending on the wire Reynolds number and the distance of the wire to the wall. Moreover, the rate of heat transfer of the hot wire in the uniform shear flow was numerically solved by using a finite difference method and was compared with the experimental results. As a result, it was found that the rate of heat loss was dependent on the dimensionless velocity gradient.
収録刊行物
-
- 日本機械学会論文集B編
-
日本機械学会論文集B編 50 (459), 2738-2743, 1984
一般社団法人 日本機械学会
- Tweet
キーワード
詳細情報 詳細情報について
-
- CRID
- 1390001206182702720
-
- NII論文ID
- 110002399497
- 130004216922
-
- NII書誌ID
- AN00187441
-
- ISSN
- 18848346
- 03875016
-
- NDL書誌ID
- 3001985
-
- 本文言語コード
- ja
-
- データソース種別
-
- JaLC
- NDL
- Crossref
- CiNii Articles
-
- 抄録ライセンスフラグ
- 使用不可