Physical Characteristics of Anti-scatter Grids According to Old and New JIS Standards
-
- ISHIKAWA MITSUO
- Department of Radiology, Kitasato University Hospital
-
- IDE TOSHINORI
- Kajima Corporation Kajima Clinic
-
- ASANO HIROSHI
- Department of Radiology, Kawasaki Municipal Hospital, Kawasaki City
-
- SAGAWA ZIN
- Department of Radiology, Kawasaki Municipal Hospital, Kawasaki City
-
- MIYAKE HIROYUKI
- Department of Radiology, Ida Municipal Hospital, Kawasaki City
-
- KAMISHIMA YUKI
- Department of Radiology, Ida Municipal Hospital, Kawasaki City
-
- NEGISHI TORU
- School of Radiologic Science, Faculty of Health Sciences, Tokyo Metropolitan University of Health Sciences
Bibliographic Information
- Other Title
-
- 新旧JIS規格による散乱X線除去用グリッドの物理的特性
Search this article
Description
JIS Z 4910(anti-scatter grids) of the JIS standards was revised in 2000. Major points of revision were the provision of general-purpose and mammographic anti-scatter grids and changes in the diameter of the measuring field and difference in the manufacturing allowance. We measured the physical characteristics (grid selectivity, contrast improvement ratio, and grid exposure factor) of [general-purpose anti-scatter grids] referring to the methods of measurement[JIS Z 4910:2000] and [JIS Z 4910:1983]using an inverter-type high-voltage generator. Physical characteristics indicated a lower value for[JIS Z 4910:2000]than for[JIS Z 4910: 1983]. [JIS Z 4910:2000] was able to measure primary radiation and scattered radiation more accurately than[JIS Z 4910:1983] because of the diameter of the measuring field and the measurement arrangement. Moreover, the physical characteristic values were influenced by radiation quality, e.g., differences in high-voltage generators. In the method of measuring stipulated by JIS, strict conditions regarding the arrangement of the measurement tools and the stability and other factors of the power output of the X-ray generator are provided for the type approval test conducted by the manufacturer.
Journal
-
- Japanese Journal of Radiological Technology
-
Japanese Journal of Radiological Technology 60 (8), 1123-1131, 2004
Japanese Society of Radiological Technology
- Tweet
Details 詳細情報について
-
- CRID
- 1390001206389629440
-
- NII Article ID
- 110003434661
-
- NII Book ID
- AN00197784
-
- ISSN
- 18814883
- 03694305
- http://id.crossref.org/issn/03694305
-
- PubMed
- 15389170
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- Crossref
- CiNii Articles
- OpenAIRE
-
- Abstract License Flag
- Disallowed