- 【Updated on May 12, 2025】 Integration of CiNii Dissertations and CiNii Books into CiNii Research
- Trial version of CiNii Research Knowledge Graph Search feature is available on CiNii Labs
- Suspension and deletion of data provided by Nikkei BP
- Regarding the recording of “Research Data” and “Evidence Data”
-
- KUZUMI Hirotoshi
- Department of Clinical Laboratory and Clinical Engineering, Department of Clinical Laboratory Medicine, Shizuoka General Hospital, Shizuoka Prefectural Hospital Organization
-
- OISHI Yuu
- Department of Clinical Laboratory and Clinical Engineering, Department of Clinical Laboratory Medicine, Shizuoka General Hospital, Shizuoka Prefectural Hospital Organization
-
- MURAKOSHI Daiki
- Department of Clinical Laboratory and Clinical Engineering, Department of Clinical Laboratory Medicine, Shizuoka General Hospital, Shizuoka Prefectural Hospital Organization
-
- HIRAMATSU Naoki
- Department of Clinical Laboratory and Clinical Engineering, Department of Clinical Laboratory Medicine, Shizuoka General Hospital, Shizuoka Prefectural Hospital Organization
Bibliographic Information
- Other Title
-
- ハイブリッドクローズドループ療法を用いて血糖管理を行った1型糖尿病の1症例
- ハイブリッドクローズドループ リョウホウ オ モチイテ ケットウ カンリ オ オコナッタ 1ガタ トウニョウビョウ ノ 1 ショウレイ
Search this article
Description
<p>Continuous subcutaneous insulin infusion (CSII) and sensor-augmented pump (SAP) therapy in patients with type 1 diabetes are close to physiological insulin secretion because they can regulate basal insulin according to the amount of individual insulin. In January 2022, insulin pumps equipped with a hybrid closed-looped (HCL) system were made available in Japan. HCL therapy is a technology with which the amount of basal insulin can be automatically adjusted on the basis of glucose levels obtained from continuous glucose monitoring (CGM) using a glucose sensor. At our hospital, a clinical laboratory technician is in charge of the introduction and guidance on the use of continuous insulin pumps. We report a case of type 1 diabetes in which blood glucose level was controlled using HCL therapy. Glycemic control with SAP therapy resulted in HbA1c levels of 7.7–8.2%. After the introduction of HCL therapy, HbA1c levels decreased to 7.0–7.2%, and blood glucose levels tended to decrease. Furthermore, time in range (TIR) increased from 51–56% with SAP therapy to 64–69% with HCL therapy. HCL therapy can increase TIR without promoting hypoglycemic events and is effective for improving patient quality of life and preventing diabetic complications.</p>
Journal
-
- Japanese Journal of Medical Technology
-
Japanese Journal of Medical Technology 72 (1), 135-140, 2023-01-25
Japanese Association of Medical Technologists