Performance of Heat Generation for the Heat Pump of Direct Heat Exchanging Method Using Humid Air

  • HIRONAKA Shuji
    Department of Chemical Engineering, Graduate School of Engineering, Kyushu University
  • HANAKI Motofumi
    Department of Chemical Engineering, Graduate School of Engineering, Kyushu University
  • WIJAYANTA Agung Tri
    Mechanical Engineering Department, Faculty of Engineering, Sebelas Maret University
  • FUKAI Jun
    Department of Chemical Engineering, Graduate School of Engineering, Kyushu University

Bibliographic Information

Other Title
  • 湿り空気を用いた直接熱交換式ヒートポンプの発熱性能
  • シメリ クウキ オ モチイタ チョクセツ ネツコウカンシキ ヒートポンプ ノ ハツネツ セイノウ

Search this article

Description

<p>The generation of steam with high temperate was investigated when saturated humid air is flowed into the adsorption heat pump used the packed bed with 13X zeolite. As a result of experiments to measure temperature of generated steam, its maximum value was over 150 °C when humid air was preheated to 70 °C. Since the maximum temperature of steam was not drastically affected by superficial velocity of humid air, it was presented that the maximum temperature does not depend on the heat transfer between humid air and zeolite under experimental conditions in this study. Hence, the maximum temperature of steam was estimated by the relationship between the adsorption equilibrium and heat balance under the assumption that both of temperature in gas and zeolite are equal. As a result, it was revealed that the maximum temperature was possible to be estimated by this method under the condition that the temperature of humid air is high.</p>