STRENGTH VERIFICATION AND COMPARISON FOR RESTORATION DESIGN OF A 60-YEAR-OLD BRIDGE
-
- DAIRAKU Hitoshi
- 九州大学大学院 工学府土木工学専攻
-
- KAJITA Yukihide
- 九州大学大学院 工学研究院社会基盤部門
-
- YAMANE Seiichi
- 株式会社コスモエンジニアリング
Bibliographic Information
- Other Title
-
- 60年程度前に施工された橋脚の復元設計についての耐力照査および比較
Description
<p> This report is based on a girder bridge constructed about 60 years ago and already dismantled. The bearing capacity of the 60-year-old piers that three engineers made the restoration design was investigated. The results showed that, depending on the design results, the yield capacity of the piers with the restored design may be estimated to be higher than that of the piers with the reinforcement revealed at the time of dismantlement. On the other hand, it was found that if the restoration design was performed with reasonable reinforcement quantity and reinforcement arrangement, even if the reinforcement arrangement was slightly different from that of the actual structure, it was unlikely to have a significant impact on the evaluation of the seismic performance of the existing piers.</p>