- 【Updated on May 12, 2025】 Integration of CiNii Dissertations and CiNii Books into CiNii Research
- Trial version of CiNii Research Automatic Translation feature is available on CiNii Labs
- Suspension and deletion of data provided by Nikkei BP
- Regarding the recording of “Research Data” and “Evidence Data”
Report of VAMAS-SCA-WG in Japan.
-
- OHMURA Takuichi
- Matsushita Technoresearch Inc.
-
- KUROKAWA Akira
- Osaka Univ.
-
- HOMMA Teiichi
- Univ. of Tokyo
-
- FUJITA Daisuke
- Univ. of Tokyo
-
- GOTO Keisuke
- Nagoya Institute of Technology
-
- UEMURA Masao
- Toyohasi Univ. of Technology
-
- TOKUTAKA Heizo
- Tottori Univ.
-
- YOSHIHARA Kazuhiro
- National Research Institute for Metals
-
- KURAHASHI Masayasu
- National Chemical Lab. for Industry
-
- ICHIMURA Shingo
- Electrotechnical Lab.
-
- OSHIMA Chuhei
- National Institute for Research in Inorganic Materials
-
- SOEDA Fusami
- Toray Research Center, Inc.
-
- FUKUDA Yasuo
- Nippon Kokan K.K.
-
- HASHIGUCHI Yoshihiro
- Nippon Steel Corp.
-
- TANAKA Kozo
- Sumitomo Chemical Co., Ltd.
-
- KUDO Masahiro
- Foundation for Promotion of Material Science and Technology of Japan
-
- HAYASHI Takayoshi
- NTT Applied Electronics Lab.
-
- TANAKA Akihiro
- ULVAC-PHI Inc.
-
- SHIOKAWA Yoshiro
- ANELVA Corp.
-
- SEKINE Tetsu
- JEOL, Ltd.
-
- SHIMIZU Ryuichi
- Osaka Univ.
Bibliographic Information
- Other Title
-
- VAMAS‐SCA‐WG in JAPAN活動報告
- VAMAS SCA WG in Japan カツドウ ホウコク
Search this article
Description
Under the auspices of the 141 comittee (Microbeam Analysis) of Japan Society for Promotion of Science, the AES working group has commenced its work on 1) the establishment of the measurement conditions and 2) the comparison of standard spectra obtained by various spectrometers. Attention was particularly paid to taking the Auger signals at an optimum position of the specimen with respect to the energy analyzer. Systematic investigations on the procedures for energy analyzers, cylindrical mirror analyzers (CMA), are reported in the first section of the present paper. Three kinds of calibration procedures were proposed for attaining the optimum positioning of the specimen with respect to the CMA. Elastic peak varied sensitively in intensity and peak shape, around the optimum position of the specimen.<BR>The comparison of AES instruments installed at several institutes was carried out by measurement of the derivative Auger peak intensity ratio for pure gold and copper under a specific measurement condition, proposed in the first section. The results are shown by the Youden plot following the laborious work performed by the ASTM comittee E-42.
Journal
-
- Shinku
-
Shinku 31 (8), 744-754, 1988
The Vacuum Society of Japan
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390282679040550400
-
- NII Article ID
- 130000863406
-
- NII Book ID
- AN00119871
-
- ISSN
- 18809413
- 05598516
-
- NDL BIB ID
- 3195173
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- NDL Search
- Crossref
- CiNii Articles
- OpenAIRE
-
- Abstract License Flag
- Disallowed