Chemiluminescence Determination of Tetracyclines Using a Tris(2,2′-bipyridine)ruthenium(II) and Potassium Permanganate System

書誌事項

タイトル別名
  • Chemiluminescence Determination of Tetracyclines Using a Tris(2,2'-bipyridine)ruthenium(II) and Potassium Permanganate System.
  • Chemiluminescence Determination of Tetracyclines Using a Tris 2 2-bipyridine ruthenium 2 and Potassium Permanganate System

この論文をさがす

抄録

A chemiluminescence method for the determination of tetracyclines was developed. The method is based on an enhancement of tetracyclines upon the chemiluminescence light emission of tris(2,2′-bipyridine)ruthenium(II). In a sulfuric acid medium, chemiluminescence light emission is generated upon continuous oxidation of tris(2,2′-bipyridine)ruthenium(II) by potassium permanganate, catalyzed by Mn(II). The light-emission intensity is enhanced when the tetracyclines are also present in the reaction system. Under the optimum conditions, the calibration curves are linear over the range 1.0×10-7 - 1.0×10-5 g/ml for tetracycline, 4.0×10-8 - 1.0×10-5 g/ml for chlortetracycline and 1.0×10-7 - 1.0×10-5 g/ml for oxytetracycline. The limits of detection (S/N=3) are 2.0×10-8 g/ml for tetracycline, 1.0×10-8 g/ml for chlortetracycline and 2.0×10-8 g/ml for oxytetracycline. The proposed method was used to determine tetracyclines in pharmaceutical formulations with good results.

収録刊行物

  • Analytical Sciences

    Analytical Sciences 15 (5), 467-470, 1999

    社団法人 日本分析化学会

被引用文献 (1)*注記

もっと見る

参考文献 (27)*注記

もっと見る

キーワード

詳細情報 詳細情報について

問題の指摘