Quantitative Determination of Total L-Carnitine in Infant Formula, Follow-up Formula, and Raw Materials by Liquid Chromatography with Tandem Mass Spectrometry

DOI PDF Web Site Web Site Web Site ほか1件をすべて表示 一部だけ表示 被引用文献2件 参考文献26件
  • NADAOKA Isao
    Department of Infant Milk and Analytical Technology, Research and Development Center, Wakodo Co., Ltd.
  • HATAKEYAMA Emi
    Department of Infant Milk and Analytical Technology, Research and Development Center, Wakodo Co., Ltd.
  • TANADA Chihiro
    Laboratory of Analytical and Bio-Analytical Chemistry, School of Pharmaceutical Sciences, University of Shizuoka
  • SAKAMOTO Tasuku
    Laboratory of Analytical and Bio-Analytical Chemistry, School of Pharmaceutical Sciences, University of Shizuoka
  • FUKAYA Shinichi
    Department of Infant Milk and Analytical Technology, Research and Development Center, Wakodo Co., Ltd.
  • AKIBA Takashi
    Department of Infant Milk and Analytical Technology, Research and Development Center, Wakodo Co., Ltd.
  • INOUE Koichi
    Laboratory of Analytical and Bio-Analytical Chemistry, School of Pharmaceutical Sciences, University of Shizuoka
  • YAMANO Yutaka
    Department of Infant Milk and Analytical Technology, Research and Development Center, Wakodo Co., Ltd.
  • TOYO’OKA Toshimasa
    Laboratory of Analytical and Bio-Analytical Chemistry, School of Pharmaceutical Sciences, University of Shizuoka

この論文をさがす

抄録

We developed a rapid and useful routine screening assay for total L-carnitine content in various infant formulas and materials by liquid chromatography coupled with a tandem mass spectrometric method (LC-MS/MS) and alkaline hydrolysis. For separation of L-carnitine, a multi-mode octadecylsilane (ODS) column was used that contained ODS ligands, anion ligands, and cation ligands to avoid using ion-pairing agents. The stable isotope L-carnitine-d3 (m/z 165 → 103/85) was used in electrospray MS/MS in the multiple reaction monitoring mode with the ion transitions of m/z 162 → 103/85 for detection and quantitation of L-carnitine. Alkaline hydrolysis of short/medium chain (C2 – C15) acyl-L-carnitines in infant formula was analyzed by LC with quadrupole time-of-flight mass spectrometry (QTOF-MS). The majority of short/medium chain acyl-L-carnitines were hydrolyzed to free L-carnitine. The overall standard deviations for L-carnitine in infant formula, follow-up formula and raw materials ranged from 2.1 to 4.0. The overall mean recoveries ranged from 90.2 to 94.2%.