- 【Updated on May 12, 2025】 Integration of CiNii Dissertations and CiNii Books into CiNii Research
- Trial version of CiNii Research Knowledge Graph Search feature is available on CiNii Labs
- 【Updated on June 30, 2025】Suspension and deletion of data provided by Nikkei BP
- Regarding the recording of “Research Data” and “Evidence Data”
Rapid Determination of Cadmium in Rice by Immunochromatography Using Anti-(Cd-EDTA) Antibody Labeled with Gold Particle
-
- SASAKI Kazuhiro
- Central research institute of electric power industry
-
- TAWARADA Kei
- The Kansai Electric Power Co., Inc.
-
- OKUYAMA Akira
- EnBioTec Laboratories Co., Ltd.
-
- KAYAMA Fujio
- Jichi Medical School
-
- ABE Kaoru
- National Institute for Agro-Environmental Sciences
-
- OKUHATA Hiroshi
- The Kansai Electric Power Co., Inc.
-
- MARUYAMA Yukinao
- EnBioTec Laboratories Co., Ltd.
-
- ARAKANE Tamami
- The General Environmental Technos Co., Ltd.
-
- MIYASAKA Hitoshi
- The Kansai Electric Power Co., Inc.
-
- FUJIKAWA Takashi
- The General Environmental Technos Co., Ltd.
-
- OHMURA Naoya
- Central research institute of electric power industry
Bibliographic Information
- Other Title
-
- 金コロイド標識抗カドミウム‐エチレンジアミン四酢酸錯体モノクローナル抗体を用いるイムノクロマトグラフィーによる米中カドミウムの簡易定量
- 金コロイド標識抗カドミウム-エチレンジアミン四酢酸錯体モノクローナル抗体を用いるイムノクロマトグラフィーによる米中カドミウムの簡易定量
- キン コロイド ヒョウシキ コウカドミウム エチレンジアミン 4サクサン サクタイ モノクローナル コウタイ オ モチイル イムノ クロマトグラフィー ニ ヨル ベイチュウ カドミウム ノ カンイ テイリョウ
Search this article
Description
A simple and rapid immunochromatography (IC) system for the detection of Cd in rice has been developed. The produced anti-Cd-EDTA antibody exhibited the equilibrium dissociation constant (Kd) for Cd-EDTA at 1.3 × 10−8 M, which was almost 100-fold tighter than Kd for the other tested EDTA-metal complex. Cadmium in rice was extracted by HCl, and the extract was introduced into a column to remove co-existing metals (such as zinc, manganese and magnesium) while retaining cadmium. After a pretreatment, IC could detect cadmium in the range from 0.01 to 0.1 mg L−1. Fifty brown rice samples were tested with the column treatment and the IC assay. The estimated cadmium concentrations from the assay were evaluated by a comparison with the results of a nitrate treatment and ICP-AES analysis for the samples. Two measurements were highly correlated, with a correlation coefficient of 0.94.<br>
Journal
-
- BUNSEKI KAGAKU
-
BUNSEKI KAGAKU 56 (1), 29-36, 2007
The Japan Society for Analytical Chemistry
- Tweet
Details 詳細情報について
-
- CRID
- 1390282679333207296
-
- NII Article ID
- 110006153717
-
- NII Book ID
- AN00222633
-
- COI
- 1:CAS:528:DC%2BD2sXot1Sjtg%3D%3D
-
- NDL BIB ID
- 8644113
-
- ISSN
- 05251931
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- NDL Search
- Crossref
- NDL Digital Collections (NII-ELS)
- CiNii Articles
- OpenAIRE
-
- Abstract License Flag
- Disallowed