Appropriate Frequency of Curtain-Exchange in Patient Rooms Based on Bacteriological Survey in a University Hospital.

  • ISHIGANE Keiko
    Section of Nursing, Toyama Medical and Pharmaceutical University
  • SAKAI Miyoko
    Section of Nursing, Toyama Medical and Pharmaceutical University
  • MURATOU Yoriko
    Section of Nursing, Toyama Medical and Pharmaceutical University
  • HIROGAMI Mariko
    Section of Nursing, Toyama Medical and Pharmaceutical University
  • SUGIMASA Miyuki
    Section of Nursing, Toyama Medical and Pharmaceutical University
  • KITAGAWA Youko
    Section of Nursing, Toyama Medical and Pharmaceutical University
  • YOSHIDA Ikuko
    Section of Clinical Laboratory, Toyama Medical and Pharmaceutical University
  • NAKAGAWA Teruaki
    Section of Pharmacy, Toyama Medical and Pharmaceutical University Hospital
  • TAUCHI Katsunori
    Second Department of Surgery, Toyama Medical and Pharmaceutical University
  • MIZUSHIMA Yutaka
    First Department of Internal Medicine, Toyama Medical and Pharmaceutical University
  • OCHIAI Hiroshi
    Department of Human Science, Faculty of Medicine, Toyama Medical and Pharmaceutical University

Bibliographic Information

Other Title
  • 細菌汚染調査からみた病室カーテンの適正交換頻度について

Search this article

Description

病室内のカーテンの細菌汚染状態を知り, カーテンの適正交換頻度を知る目的で, 10病室 (一般病室4, MRSA隔離室6) のカーテンに付着している細菌をバイオエアーチエッカーを用い1週間隔で5回調査した.その結果, 下記の成績が得られた.1) 4週間を通じてカーテンの付着菌数の累積的増加は認められなかった.2) 分離菌ではブドウ球菌がもっとも多く, ついでグラム陽性桿菌, 真菌の順であった.3) MRSA隔離室のほうが一般病室より多くの菌数が検出された.4) MRSA隔離室6室のうち2室で濃厚なMRSA汚染が認められた.5) 消毒用エタノール噴霧はいずれの細菌の除菌にも有効であった.以上より, カーテンの交換頻度はMRSA隔離室では患者の退室ごとに, また一般病室では肉眼的汚れに応じ, 年3-4回定期的に交換するのが適当ではないかと考えられた.