貫流羽根車内部の非定常圧力分布

書誌事項

タイトル別名
  • Unsteady Pressure Distribution inside a Cross-Flow Impeller
  • カンリュウ ハネグルマ ナイブ ノ ヒテイジョウ アツリョク ブンプ

この論文をさがす

抄録

The authors experimentally studied the characteristics of the flow around/inside a cross-flow fan, namely, a cross-flow impeller. In order to eliminate complicated influence of many casing factors, the impeller rotates in open space without any casings. As a result, at the singular aspect ratio L/D2=0.6, at which the outflow rate Q0 out of the impeller and the maximum vorticity ωmax attain the maximum values, the authors reveal minute fluctuating pressures on impeller's end wall. In some pressure measurements, the eccentric vortex inside the impeller is prevented to revolute by the insertion of a tongue, in order to consider the spatial structure of flow more precisely. The authors have confirmed that the influence of the tongue insertion is negligible. And, the authors confirmed such Reynolds-number effect as a time-mean pressure coefficient Cpmean decreases with increasing Reynolds number for Re ≤ 4.0×103. Based on phase-averaging technique by the synchronised measurement of a impeller-rotation-counter signal, the pressure distribution inside the impeller shows that the minimum value is at θ =300deg.

収録刊行物

  • ターボ機械

    ターボ機械 41 (12), 743-753, 2013

    一般社団法人 ターボ機械協会

詳細情報 詳細情報について

問題の指摘

ページトップへ