- 【Updated on May 12, 2025】 Integration of CiNii Dissertations and CiNii Books into CiNii Research
- Trial version of CiNii Research Knowledge Graph Search feature is available on CiNii Labs
- Suspension and deletion of data provided by Nikkei BP
- Regarding the recording of “Research Data” and “Evidence Data”
Comparative effects of two different artificial body fluids on <I>Candida albicans </I>adhesion to soft lining materials
-
- VURAL Caner
- Department of Biology, Microbiology Section, Faculty of Science, Ege University
-
- OZDEMIR Guven
- Department of Biology, Microbiology Section, Faculty of Science, Ege University
-
- KURTULMUS Huseyin
- Department of Prosthodontics, Faculty of Dentistry, Ege University
-
- KUMBULOGLU Ovul
- Department of Prosthodontics, Faculty of Dentistry, Ege University
-
- ÖZCAN Mutlu
- Dental Materials Unit, Center for Dental and Oral Medicine, Clinic for Fixed and Removable Prosthodontics and Dental Materials Science
Bibliographic Information
- Other Title
-
- Comparative effects of two different artificial body fluids on Candida albicans adhesion to soft lining materials
Search this article
Description
This study investigated the C. albicans adhesion to cold- and heat-polymerized soft lining materials that were initially incubated in two different artificial body fluids, namely saliva and nasal secretion, and examined the surface roughness the materials (cold and heat polymerized soft liner) tested in vitro. Cold (Visco Gel) and heat-polymerized (Molloplast B) soft liner specimens (N=32, n=8 per group) (10×10×1.5 mm) were randomly produced to express the relationship between surface roughness and contamination, and influence of body fluids, and incubated in 1.5 ml contaminated solutions for 2 h. After fixation, all of materials were evaluated under optical microscope (×400) and SEM. Surface roughness measurements were examined with profilometre for each material. Data were analyzed using two-way ANOVA, Tukey’s HSD and Dunnett T3 tests (α=0.05). Material type (p<0.05) and contamination media (p<0.05) showed a significant influence on the C. albicans adherence. The surface roughness of cold polymerized soft liner (Visco Gel) was significantly higher than heat-polymerized soft liner (Molloplast B) (p<0.05).
Journal
-
- Dental Materials Journal
-
Dental Materials Journal 29 (2), 206-212, 2010
The Japanese Society for Dental Materials and Devices
- Tweet
Details 詳細情報について
-
- CRID
- 1390282679694374528
-
- NII Article ID
- 10026193024
-
- NII Book ID
- AA10443149
-
- ISSN
- 18811361
- 02874547
-
- Text Lang
- en
-
- Data Source
-
- JaLC
- Crossref
- CiNii Articles
-
- Abstract License Flag
- Disallowed