単結晶ダイヤモンド二次元切削における工具すくい面温度の測定

書誌事項

タイトル別名
  • Measurement of Tool Face Temperature in Orthogonal Diamond Cutting.
  • タンケッショウ ダイヤモンド 2ジゲン セッサク ニ オケル コウグ スクイメ

この論文をさがす

抄録

Tool face temperature of single crystal diamond in high precision orthogonal cutting of aluminum and copper is measured using two-color pyrometer with an optical fiber. The infrared rays radiated from the chip-tool interface and transmitted through the diamond tool are accepted by an optical fiber and led to two-color detectors of different spectral sensitivity. Temperature distribution on the tool face is analyzed by employing finite element method and calculated results are applied to the estimation of the maximum temperature on the tool face. The results obtained are as follows; (1) The technique developed is suitable for measuring the tool face temperature in single crystal diamond cutting. (2) Output wave of temperature was clearly recorded. The tool face temperature measured is approximately 190°C for Al and approximately 220°C for Cu when cutting speed was about 620m/min. (3) The temperature increases with the increase of cutting speed. (4) The temperature on the tool face measured is in good agreement with that calculated.

収録刊行物

  • 精密工学会誌

    精密工学会誌 64 (6), 892-896, 1998

    公益社団法人 精密工学会

被引用文献 (5)*注記

もっと見る

参考文献 (8)*注記

もっと見る

詳細情報 詳細情報について

問題の指摘

ページトップへ