書誌事項
- タイトル別名
-
- C214 Visualization Test Using Piping Group Mock Up Specimen for Evaluation of Wastage Phenomena in Steam Generator for FBR
抄録
There is a need for quantitative evaluation of wastage phenomena in steam generator for FBR. We focused attention on liquid droplet impingement erosion (LDIE) in wastage phenomena and performed basic study with piping group mock up specimen for quantitative evaluation of LDIE. First, we did visualization test of high pressure and high speed jet into the water. Test section mock up the crack of heat exchanger tube and neighboring heat exchanger tubes. We did the test under the following test conditions. Upstream pressure is 0.3MPa, vapor temperature is 300K, crack width is 0.1mm, and crack length is 40mm. (crack diameter is 0.2mm) Second, we did pressure and temperature measurement test in the same test conditions as before. We evaluated jet behavior at test section by those two tests. In addition, we did two phase flow analysis of the jet with TRAC code.
収録刊行物
-
- 動力・エネルギー技術の最前線講演論文集 : シンポジウム
-
動力・エネルギー技術の最前線講演論文集 : シンポジウム 2012.17 (0), 317-318, 2012
一般社団法人 日本機械学会
- Tweet
キーワード
詳細情報 詳細情報について
-
- CRID
- 1390282680862749824
-
- NII論文ID
- 110009919703
-
- ISSN
- 24242950
-
- 本文言語コード
- ja
-
- データソース種別
-
- JaLC
- Crossref
- CiNii Articles
-
- 抄録ライセンスフラグ
- 使用不可