Comparison of Optical Biometers OA-2000 and ALADDIN
-
- Goto Yasuhito
- Department of Ophthalmology, Okayama University Hospital
-
- Inagaki Asuka
- Department of Ophthalmology, Okayama University Hospital
-
- Fujiwara Atsushi
- Department of Ophthalmology, Okayama University Hospital
-
- Kanenaga Keisuke
- Department of Ophthalmology, Okayama University Hospital
-
- Sakate Mio
- Department of Ophthalmology, Okayama University Hospital
-
- Akita Juri
- Department of Ophthalmology, Okayama University Hospital
-
- Shiraga Fumio
- Department of Ophthalmology, Okayama University Hospital
Bibliographic Information
- Other Title
-
- 光学式眼軸長測定装置OA-2000とALADDINの比較
Search this article
Description
<p>[Purpose] To compare axial length (AL) measurement acquisition rate and measurement accuracy between optical biometers OA-2000 using fourier-domain (FD) and ALADDIN using time-domain (TD) in patients with cataract.</p><p>[Subjects and methods] Subjects were 51 eyes of 34 patients (mean age: 71.9 ± 9.6 years) measured by the two optical biometers before cataract surgery. Measurement by both devices was performed on the same day by the same examiner. AL, AL measurement acquisition rate according to the classified cataract grade, and the coefficient of variance (CV) obtained by both devices were compared.</p><p>[Results] The grades for the nuclear sclerosis based on the Emery-Little classification were as follows: grade 1 (9.8%), grade 2 (68.6 %), and grade 3 (21.6 %). The mean axial length measurements were 23.33 ± 1.11 mm by FD and 23.35 ± 1.12 mm by TD showing no significant difference between the two devices (P = 0.732). However, the AL measurement acquisition rate for TD was significantly lower than the rate for FD (P < 0.01, Chi-Square test) in patients with grade 2 nuclear sclerosis. FD showed a significantly smaller mean CV (0.0003 ± 0.0002) than TD (0.0022 ± 0.0013), indicating a higher stability in the measurements by FD (P < 0.01, paired t-test).</p><p>[Conclusions] Optical biometer with FD showed a higher AL measurement acquisition rate and better measurement accuracy than that with TD.</p>
Journal
-
- JAPANESE ORTHOPTIC JOURNAL
-
JAPANESE ORTHOPTIC JOURNAL 47 (0), 109-115, 2018
JAPANESE ASSOCIATION OF CERTIFIED ORTHOPTISTS
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390282763103341568
-
- NII Article ID
- 130007608489
-
- ISSN
- 18839215
- 03875172
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- Crossref
- CiNii Articles
- OpenAIRE
-
- Abstract License Flag
- Disallowed