Comparison of the Efficacy of Cryoballoon Ablation for Paroxysmal and Persistent Atrial Fibrillation
-
- Iso Kazuki
- Division of Cardiology, Department of Medicine, Nihon University School of Medicine, Tokyo, Japan
-
- Watanabe Ichiro
- Division of Cardiology, Department of Medicine, Nihon University School of Medicine, Tokyo, Japan
-
- Okumura Yasuo
- Division of Cardiology, Department of Medicine, Nihon University School of Medicine, Tokyo, Japan
-
- Nagashima Koichi
- Division of Cardiology, Department of Medicine, Nihon University School of Medicine, Tokyo, Japan
-
- Takahash Keiko
- Division of Cardiology, Department of Medicine, Nihon University School of Medicine, Tokyo, Japan
-
- Arai Masaru
- Division of Cardiology, Department of Medicine, Nihon University School of Medicine, Tokyo, Japan
-
- Watanabe Ryuta
- Division of Cardiology, Department of Medicine, Nihon University School of Medicine, Tokyo, Japan
-
- Kurokawa Sayaka
- Division of Cardiology, Department of Medicine, Nihon University School of Medicine, Tokyo, Japan
-
- Ohkubo Kimie
- Division of Cardiology, Department of Medicine, Nihon University School of Medicine, Tokyo, Japan
-
- Nakai Toshiko
- Division of Cardiology, Department of Medicine, Nihon University School of Medicine, Tokyo, Japan
-
- Hirayama Atsushi
- Division of Cardiology, Department of Medicine, Nihon University School of Medicine, Tokyo, Japan
-
- Sonoda Kazumasa
- Division of Cardiology, Department of Medicine, Tokyo Rinkai Hospital., Tokyo, Japan
-
- Tosaka Toshimasa
- Division of Cardiology, Department of Medicine, Tokyo Rinkai Hospital., Tokyo, Japan
この論文をさがす
説明
Background: Similar clinical outcomes have been demonstrated following pulmonary vein (PV) isolation (I) by radiofrequency catheter and cryoballoon ablation (CBA) in patients with paroxysmal atrial fibrillation (PAF). However, no comparison of the clinical outcome in patients with PAF and persistent AF (PerAF) by CBA has been reported to date. The purpose of this study was to compare the efficacy of PVI in patients with PAF and PerAF. Methods: CBA based PVI using a second-generation 28-mm balloon was performed in 58 patients with PAF and 32 with PerAF. Follow-up (FU) was based on outpatient clinic visits at 1, 3, 6, and 12 months, which included Holter electrocardiograms and ambulatory event electrocardiograms. Results: The freedom from atrial tachyarrhythmia recurrences following a single cryoballoon ablation in patients with PAF and PerAF did not differ significantly between the PAF and PerAF patients over a relatively shorter follow-up period, as estimated by the Kaplan-Meir method. Conclusion: CB-based PVI had similar efficacy for both PAF and PerAF.
収録刊行物
-
- 日大医学雑誌
-
日大医学雑誌 78 (1), 21-25, 2019
日本大学医学会
- Tweet
詳細情報 詳細情報について
-
- CRID
- 1390564238096272256
-
- NII論文ID
- 130007627729
-
- NII書誌ID
- AN0018408X
-
- ISSN
- 18840779
- 00290424
-
- NDL書誌ID
- 029570755
-
- 本文言語コード
- ja
-
- データソース種別
-
- JaLC
- NDL
- Crossref
- CiNii Articles
-
- 抄録ライセンスフラグ
- 使用不可