Usefulness of endoscopic ultrasonography with gel-immersion endoscopy for esophageal varices
-
- Kato Tsunetaka
- Department of Endoscopy, Fukushima Medical University Hospital Department of Gastroenterology, Fukushima Medical University School of Medicine
-
- Hikichi Takuto
- Department of Endoscopy, Fukushima Medical University Hospital
-
- Nakamura Jun
- Department of Endoscopy, Fukushima Medical University Hospital Department of Gastroenterology, Fukushima Medical University School of Medicine
-
- Yanagita Takumi
- Department of Endoscopy, Fukushima Medical University Hospital Department of Gastroenterology, Fukushima Medical University School of Medicine
-
- Takagi Tadayuki
- Department of Gastroenterology, Fukushima Medical University School of Medicine
-
- Otsuka Mitsuru
- Department of Gastroenterology, Fukushima Medical University School of Medicine
-
- Noguchi Yuki
- Department of Gastroenterology, Fukushima Medical University School of Medicine
-
- Kameoka Eisuke
- Department of Gastroenterology, Fukushima Medical University School of Medicine
-
- Ohira Rei
- Department of Gastroenterology, Fukushima Medical University School of Medicine
-
- Ohira Hiromasa
- Department of Gastroenterology, Fukushima Medical University School of Medicine
Bibliographic Information
- Other Title
-
- 食道静脈瘤に対するゲル充填下超音波内視鏡検査の有用性
- ショクドウ ジョウミャクリュウ ニ タイスル ゲル ジュウテン カ チョウオンパ ナイシキョウ ケンサ ノ ユウヨウセイ
Search this article
Description
<p>It has been difficult to obtain good EUS images of esophageal varices (EVs) using the water-filling EUS technique. The purpose of this study was to evaluate the usefulness of gel-immersion EUS for EVs compared with water-filling EUS. We retrospectively evaluated EUS image quality, procedure time, diagnostic ability of local veins in the EVs, and adverse events in EVs patients who underwent EUS prior to endoscopic treatment. EUS image quality was rated on a 4-point scale from 4 (very good) to 1 (poor), and operators were classified as “expert” if they had more than 10 years of medical experience and “non-expert” if they had less than 10 years of medical experience. Eighteen gel-immersion-EUS and 17 water-filling EUS patients were included in this study, and there was no difference in operators between the two groups. Image quality scores were higher for gel-immersion-EUS at 4 (3-4) and water-filling EUS at 2 (1-3) (p < 0.001). Diagnostic ability of Pv was also higher with gel-immersion-EUS (p = 0.03). Procedure time was 6.5 (4-14) minutes for gel-immersion-EUS and 4 (2-10) minutes for water-filling EUS with gel-immersion-EUS (p < 0.001). No adverse events occurred in either case. gel-immersion-EUS for EVs was safe and could be performed safely with good image quality.</p><p>In conclusion, in hemodynamic diagnosis by EUS for EVs, gel-immersion-EUS provided better EUS images and better evaluation of Pv than water-filling EUS, even for non-expert operators.</p>
Journal
-
- Japanese Journal of Portal Hypertension
-
Japanese Journal of Portal Hypertension 30 (4), 278-284, 2024
The Japan Society for Portal Hypertension
- Tweet
Details 詳細情報について
-
- CRID
- 1390584121651098880
-
- NII Book ID
- AA11349565
-
- ISSN
- 21866376
- 13448447
-
- NDL BIB ID
- 033941428
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- NDL Search
-
- Abstract License Flag
- Disallowed