SEISMIC PERFORMANCE OF A LARGE STEEL UNIT HOUSE FURBISHED WITH EXTERNAL WALL PANELS
-
- MATSUDA Ryosuke
- Graduate School of Eng., Hokkaido Univ.
-
- OKAZAKI Taichiro
- Faculty of Eng., Hokkaido Univ.
-
- NAGAE Takuya
- Faculty of Eng., Nagoya Univ.
-
- MATSUMIYA Tomohiro
- Faculty of Arch., Kindai Univ.
-
- TAKAHASHI Noriyuki
- Faculty of Eng., Tohoku Univ.
-
- KANZAKI Yoshikazu
- FUJI SASH CO.,LTD.
-
- FUKUI Takahiro
- FUJI SASH CO.,LTD.
-
- IIJIMA Toshihiko
- IIJIMA Structural Design Office
-
- KIRIYAMA Yoshiro
- INVISIBLE design
-
- KAJIWARA Koichi
- E-Defense, NIED
Bibliographic Information
- Other Title
-
- 外壁パネル付大型ユニットハウスの耐震性能を検証する実験
Abstract
<p>Further shake table tests were conducted to examine the seismic performance of unit houses (prefabricated metal houses). A specimen comprising 4 unit-house units connected vertically and horizontally was subjected repeatedly in the long-side direction to the JMA Kobe record. The nonstructural, external wall panels increased the strength of the specimen twofold. The energy dissipated by repeated slipping of the slip-critical bolted connections equaled 88% of the total energy dissipated by the structural frame.</p>
Journal
-
- AIJ Journal of Technology and Design
-
AIJ Journal of Technology and Design 28 (69), 679-684, 2022-06-20
Architectural Institute of Japan
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390855422511313536
-
- ISSN
- 18818188
- 13419463
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- Crossref
-
- Abstract License Flag
- Disallowed