書誌事項
- タイトル別名
-
- SEISMIC PERFORMANCE OF A LARGE STEEL UNIT HOUSE FURBISHED WITH EXTERNAL WALL PANELS
抄録
<p>Further shake table tests were conducted to examine the seismic performance of unit houses (prefabricated metal houses). A specimen comprising 4 unit-house units connected vertically and horizontally was subjected repeatedly in the long-side direction to the JMA Kobe record. The nonstructural, external wall panels increased the strength of the specimen twofold. The energy dissipated by repeated slipping of the slip-critical bolted connections equaled 88% of the total energy dissipated by the structural frame.</p>
収録刊行物
-
- 日本建築学会技術報告集
-
日本建築学会技術報告集 28 (69), 679-684, 2022-06-20
一般社団法人 日本建築学会
- Tweet
詳細情報 詳細情報について
-
- CRID
- 1390855422511313536
-
- ISSN
- 18818188
- 13419463
-
- 本文言語コード
- ja
-
- データソース種別
-
- JaLC
- Crossref
-
- 抄録ライセンスフラグ
- 使用不可