Evaluation of the wearing position of a cartilage conduction type transducer by adults with conductive hearing loss: Changes in pure tone threshold and speech intelligibility depending on head fixation position

DOI

Bibliographic Information

Other Title
  • 伝音性難聴のある成人による軟骨伝導型振動子の装着位置の検討
  • — 頭部固定位置による純音聴力レベルと文章了解度の変化 —

Abstract

<p>For one participant with conductive hearing loss, pure tone threshold was measured using a cartilage conduction transducer, and subjective evaluation of phoneme balance sentences was performed. The results of the experiment showed that the hearing level near the mastoid process was the best. Deterioration of pure tone hearing was observed in the following order: around the temple, around the external auditory canal, around the tragus, and the angle of the mandible. In evaluating phoneme balanced sentences, participants reported that it was easiest to hear when the vibrator was fixed near the mastoid process.</p>

Journal

Details 詳細情報について

  • CRID
    1390862478333132672
  • DOI
    10.60274/asjsc.sc-2024-10
  • ISSN
    27582744
  • Text Lang
    ja
  • Data Source
    • JaLC
  • Abstract License Flag
    Allowed

Report a problem