High precision calibration method of intrinsic parameters for fish-eye cameras

この論文をさがす

説明

Fish-eye camera is suitable for 3D shape measurements at short range, because it has very wide depth of field and very wide angle of view. Most traditional calibration methods of the parameters for 3D shape measurements use a calibration chart drawn by white and black dual level lattices. However, edges of lattices are blurred by the influence of spatial LPF characteristics of image resolution. In this paper, we propose a high precision calibration method of the intrinsic parameters using slanting brightness lattice patterns with lower spatial frequency component.

収録刊行物

詳細情報 詳細情報について

  • CRID
    1872835442489164288
  • DOI
    10.1117/12.825586
  • ISSN
    0277786X
  • データソース種別
    • OpenAIRE

問題の指摘

ページトップへ